General
Power Output   5 to 50 watts continuously adjustable
RF Output Impedance   50 ohms, VSWR less than 2:1 for full output, protected for open and short circuit; BNC connector
RF Harmonic and Spurious   60 dB or more below rated output
Frequency Range   87 to 109 MHz in 10 kHz steps
Frequency Control   Phase locked loop frequency synthesis from highly stable master oscillator
Frequency Stability   +/-250 Hz
Modulation Type   Direct carrier frequency modulation
Modulation Capability   +/-200 kHz deviation
Modulation Indication   Bargraph: 5% increments; Digital meter: 0.1% resolution

Composite Operation
Composite Inputs   Balanced, unbalanced and test
Composite Input Impedance   5,000 ohms, nominal
Composite Input Level   1.25 volts RMS (3.50 volts peak-to-peak) for +/-75 kHz deviation
Composite Amplitude Response   +/-0.2 dB, 20 Hz to 100 kHz
Composite Phase Response   +/-0.5 degrees, 20 Hz to 75 kHz
Composite Group Delay Variation   +/-25 ns, 20 Hz to 75 kHz
Composite Total Harmonic Distortion   0.005% using "A" weighted filter
Composite Intermodulation Distortion   0.005%, 60 Hz/7 kHz, 4:1 using CCIR-2k filter
Composite FM S/N Ratio
(FM Noise)
  90 dB @ 400 Hz, 75 microsecond de-emphasis measured using "A" weighted filter
Three SCA Inputs   Balanced or unbalanced
SCA Input Impedance   15,000 ohms, nominal
SCA Input Level   1.25 volts RMS for 10% injection
SCA Amplitude Response   +/-0.3 dB, 40 kHz to 100 kHz

Stereo Operation   Most stereo performance parameters are determined by the stereo generator used. The following parameters are influenced by the RF system. These specifications assume that the stereo generator is a state-of-the-art generator.
Stereo Separation   50 dB minimum; 50 Hz to 15 kHz  (60 dB or better, 400 Hz to 7.5 kHz typical)
FM Noise   -72 dB referenced to 400 Hz, 75 kHz deviation; measured with 75 microsecond de-emphasis within a 20 Hz to 15 kHz bandwidth

SCA Operation   Most SCA performance parameters are determined primarily by the SCA generator used.

Electrical
Input Power   115V or 230V +/-10%; 50/60 Hz +/-5%; single phase, 200 watts maximum

Operating Environment
Temperature Range   -4 to +131 degrees F (-20 to +55 degrees C)
Altitude Range   0 to 15,000 ft. (0 to 4,600 m)
Relative Humidity Range   0 to 95%

Mechanical
Mounting   Equipped with rack mounting sides
Size   17.5 in. (44.45 cm) wide, centered in a 19 in. (48.26 cm) rack-mounting panel; 22 in. (55.88 cm) deep; 5.25 in. (13.34 cm) high
Weight   Approximately 31.5 lbs. (14.3 kg)